Xraytrace documentation

raytracing software for x-ray standing wave calculations

User Tools

Site Tools


au_particles

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
au_particles [2018/01/27 09:31]
pklapetek created
au_particles [2018/01/27 22:47] (current)
pklapetek
Line 1: Line 1:
 ===== Au particles ===== ===== Au particles =====
 +
 +An example of measurements on Au particles of different heights on silicon is in work of by Tiwari et. al [1]. The measurement is performed for 15 keV incident beam energy, i.e. 0.0826 nm wavelength.
 +
 +Two graphs taken from Ref [1] are show here for reference, top one is for 90 nm particles and bottom one for 250 nm particles.
 +
 +{{ :​au90.png?​400 |}}
 +
 +{{ :​au250.png?​400 |}}
 +
 +
 +With {{samples:​au_sphere_90nm.tar.gz|these parameter files}} we have obtained the results using simple and raytracing model (on GPU).
 +
 +{{ :​ausimple.png?​400 |}}
 +
 +
 +==== Reference ====
 +
 +[1] Tiwari, Das, and Bedzyk, Appl. Phys. Lett. 107, 103104 (2015)
  
au_particles.1517041882.txt.gz ยท Last modified: 2018/01/27 09:31 by pklapetek